Cement Manufacturers Association (CMA)

17 tube bundles along with drives by modifying steam ejector to withstand higher steam flow from the turbine due to boilers & piping modification. Figure 1: 20.4 MW SteamGenerator Modified TG Lube Oil System Total steam generation increase – 14 TPH TG inlet steam temp increase - 48°C Power Gain – 4.0 MWh