Cement Manufacturers Association (CMA)

Page 56 Technology Adopted Various brain storming sessions conducted to optimize ESP charging keeping Environment norms strictly in mind for stack emission. ESP Field Charge Ratio as the ratio of the number of on cycle to the charging value or base voltage value maintained charge ratio adjusted from 1:1 to loading. Derived controller settings (mA limit settings and charge ratio) set at optimum values. At the same time Rapping operation charging. Heater Operation Automation Close loop monitoring scheme adopted for continuous monitoring and control of Heater of 90DegC to 120DegC. RTD (Pt-100) as sensor used for temperature measurement inside heater chamber and PID controller setup used to control Heater operation. Sensor RTD) moun ng Controller Setup for close Loop Monitoring & control