Cement, Energy and Environment

PSD analyzer, the impact of making minute adjustment to the milling process can be seen in real me. Earlier the standard devia on of the 01 day & 28 days compressive strength of PPC grade were 1.39 Mpa and 1.59 Mpa respec vely. Now the opera ng team stabilized the mill according to real me data and it has been observed that standard devia on has been reduced to 0.80 Mpa & 0.32 Mpa for one day and twenty eight days compressive strength data. The Xop x online par cle size distribu on analyzer is the eye of the control room operators and forms the basis on which opera ng parameters are adjusted. In real me, changes within the process are seen by operators, allowing them to respond instantly to those changes. They can make adjustment promptly, correctly and can see the result of those changes. Tradi onal offline par cle sizing can never give this element of Control. Proper suc on in sampling path is desired for good results if suc on is not proper due to any reason then accuracy of result is not good. 60 Standard Devia on-: 1.39 Mpa

RkJQdWJsaXNoZXIy MTYwNzYz