83 The Variable Refrigerant Volume HVAC System is a relatively new technology developed by Daikin, the world’s leading HVAC manufacturer. Precise individual control and inverter technology minimize energy consumption to deliver optimum energy savings. Energy efficient technologies installed in New Admin Building New VRV systems offer high levels of energy efficiency, as well as flexibility. They operate quietly and provide the user full control of the environmental temperatures. HVAC System, LED Lights and Occupancy Sensor a. Energy Saving Operation Modular design of outdoor units and wide selection of indoor units ensure system designs that are ideally suited to the environment where they are installed. b. Adaptable Design Lighting Load Electrical Load HVAC Electronics & Misc. TOTAL 11620 4695 165000 9030 190345 New Administrative Building Connected Load Detail inWatt Table 1 – Connected Load of New Administrative Building Fishbone diagram represent progressive journey of JKWCW ADM building to 5 star label certi cation Figure 2: Work done to achieve 5 star Label Certi cation Design level Engineering Procurement of Star labelled HVAC system & LED light O ce lights controlled through occupancy sensor Rain water positive water harvesting pit construction Building design to utilize day light Installation of roof top 150 KW solar panel Enrgy e cient electrical & electronic equipment installed Study applying for 5 star label certi cation